Baader Planetarium’s First Light: DeltaRho 350

I had the chance to test the DeltaRho 350 f/3 Astrograph (DR350) with the serial number 0003 – all in all this solution is absolutely remote capable! You can read my first impressions and experiences here:

Setup and installation

The unit is very well made and in combination with PlaneWave’s focuser and de-rotator, it is quite a massive unit and surprisingly heavy. The center of gravity is at the back of the telescope.

The PWI4 (beta) software that operates the DR350 telescope installs quickly and works immediately with Maxim DL. If you have problems, take a look at the USB settings in PWI4, which is used to operate the fans, the heating of the secondary and primary mirrors, the focuser, and the rotator. The DR350 is controlled purely by the software.

With Maxim DL, I have been able to perform every working routine of focusing and field tilt measurement very well. The results are consistent and extremely important for accurate alignment! After I attached the QHY 600M PH, BSI Cooled Cameras (#1931162 , € 5750 ) with the help of the Baader M68 system, the DR350 was ready for use.

There is a saying among astronomers that with a new hardware the weather is bad for many weeks… Now I have to give some credence to this, because due to high and ground fog, or clouds that did not have a gap, the process of adjustment dragged on for a long time… and the first result was still far away.

The adjustment procedure before the First Light

The bottom line is that the adjustment is easy to do – but it is very important that the image fits! The primary and secondary mirrors are laser-aligned at PlaneWave in the US; the secondary and the tilter must then bring the camera into optimal alignment.
TIP: The night must be good and clear for the field tilt measurement results to be correct! In case of haze, fog or clouds I advise against it!

Following are my steps in an overview to get the DR350 to work.

  1. Determine the focus! Use a normal focus routine. The focus point that you have determined must be used as a basis for the field tilt measurement.
  2. The field measurement: For this, I use a total of 5 shots: two before and two after the focus, plus one corresponding to the entered base value. The distances are 500 steps each at Bin2!
  3. From this, the best focus is now determined. The evaluation shows the field and how the tilt is. Afterward, the field can be corrected either at the PW-Tilter with the platelets or with the Baader M68-Tilter (if it is available in the system).
  4. And now: run the routine again and repeat the steps of the adjustment until the deviation is below 5micron!
  5. Check the center of the secondary mirror at Bin1, if all in all is exactly centered!
  6. Then do one last final pass with the focus/field tilt routine!

 

 

 

 

 

 

 

 

 

Once I had achieved the values that Planewave specifies, imaging began!

The Basics

For each shot, I paid attention to the following points:

  • Cool-down: This is where I run the fans until the difference between ambient and catch + primary mirror is less than 1.5°C;
  • I did not have any fan active during the exposures!
  • The mirror heaters were in use when I had a lot of dew (unfortunately often). But they only ran until the mirror was completely clear again; then it was brought back to temperature with the side fans!

First Light

I shot in luminance and with RGB (the new Baader LRGB CMOS optimized filter is just top!). I compared the focus in Lum with R/G/B, again the system is very balanced, and there is not much variation in the values.

Now I just had to have a really good night with no moon (not a good combination at f/3), and good to very good conditions. Often there was good weather until the end of twilight, but then very often it became difficult. (Fog formation!)

The image of IC59 and IC63: Here the conditions were good for red, just good for green, and for blue, I unfortunately already had a lot of haze and ground fog. Exposures were only 60sec per single shot, with the QHY 600M in Bin2 (Gain 26).

The number of all exposures was well over 100, leaving 74min in RGB. The flats were taken with film, darks, and bias for data reduction in PixInsight.

The result is very promising with the background of not ideal conditions! For ONLY RGB this is really good!

IC 59 and IC63 were taken in less than ideal conditions (lots of haze when taking blue images) with PlaneWave Delta Rho 350 f/3 telescope with Cassegrain focus, camera QHY600M in Bin2 (Gain 26), exposure: 60 seconds per frame © Christoph Kaltseis

My first CONCLUSION

It is top hardware, which needs absolute care with the adjustment but rewards you with very good image results. And the system is absolutely remote capable!

A dream telescope? Yes – without a doubt!

support@hoydenbranding.com

Recent Posts

Optical Testing at PlaneWave

Optical Testing at PlaneWave At PlaneWave, our observatory system testing is more rigorous, thorough, and…

54 years ago

Hard Labor Creek Observatory

An Update from Georgia State University In March 2022, the PlaneWave installation team embarked on…

54 years ago

PlaneWave and Sea West Selected by Mynaric for Space Development Agency’s Optical Ground Station Program

FOR IMMEDIATE RELEASE Adrian, MI, January 4, 2024 – PlaneWave Instruments and Sea West Observatories…

54 years ago

PlaneWave Installs CDK500 Observatory System at Eastern Arizona College

Eastern Arizona College's Payson Campus has recently become home to a state-of-the-art CDK500 Observatory System,…

54 years ago

PlaneWave Instruments Installs First-Ever Ski Resort Telescope in Jackson Hole

Recently, our dedicated installation team under the guidance of Cameron Vittiglio, Field Experience Manager, and…

54 years ago

Event Recap: A Successful Open House & Science Expo

The skies above PlaneWave Instruments were abuzz with excitement this past weekend as we hosted…

54 years ago