With the advantage of low readout noise and high-speed readout, CMOS technology has revolutionized astronomical imaging. A monochrome, back-illuminated, high-sensitivity, astronomical imaging camera is the ideal choice for astro-imagers.

  • QHY600PH-M is the Photographic monochrome version.
  • QHY600PH-M SBFL is the Photographic short back focus length monochrome version.
  • QHY600PH-C is the Photographic color version.
  • QHY600PH-C SBFL is the Photographic short back focus length color version.
About the QHY600PH

Equipped with a Sony IMX455, the QHY600 is a back-illuminated Scientific CMOS Camera with extremely low dark current (0.002e/p/s@-20C) using SONY’s Exmor BSI CMOS technology. QHY600 is also a zero amplifer glow camera.

The QHY600 has only one electron of read noise at high gain and full resolution and 4FPS readout speed.  One electron of read noise means the camera can achieve a SNR>3 at only 4 to 6 photons. This is perfect performance when conditions are photon limited, i.e., short exposures, narrow band imaging, etc., making this large area sensor ideal for sky surveys, time domain astronomy, fluorescence imaging, DNA sequencing and microscopy.

202104147072GB DDR3 image buffer

In order to provide smooth uninterrupted data transfer of the entire 60MP sensor at high speed, the QHY600 has 2GB DDR3 image buffer. The pixel count of the latest generation of CMOS sensors is very high resulting in greater memory requirements for temporary and permanent storage.  For example, the QHY600 sensor produces about 120MB of data per frame.  The data band-width is also increased from the original 16-bits to the current 32-bits.  Transferring such a large file sizes necessarily requires the camera to have sufficient memory. The QHY600 has adopted a large-capacity memory of up to 2GB.  Data throughput is doubled. This large image buffer meets the needs of high-speed image acquisition and transmission of the new generation of CMOS, making shooting of multiple frames smoother and less stuttered, further reducing the pressure on the computer CPU.

Another advantage is that when using some computers that do not have fast processors or have poor support for USB 3.0, the computer can’t transfer high-speed data well, and the data is often lost. The DDR can buffer a lot of image data and send it to the computer. Even if the USB 3.0 transmission frequently gets suspended, it will ensure that data is not lost. There are options in SharpCap to turn DDR buffering on or off. The current version of the ASCOM driver works in DDR mode.

Extended Full Well Capacity and Multiple Read Modes

With a pixel size of 3.76um, these sensors already have an impressive full well capacity of 51ke.  Nevertheless, QHYCCD has implemented a unique approach to achieve a full well capacity higher than 51ke- through innovative user controllable read mode settings.  In extended full well readout mode, the QHY600 can achieve an extremely large full-well charge value of nearly 80ke- and the QHY268C can achieve nearly 75ke-.  Greater full-well capacity provides greater dynamic range and large variations in magnitude of brightness are less likely to saturate.  The QHY600 / 268C have three readout modes with different characteristics.

20200222073624670

 

20210602255Native 16 bit A/D: The new Sony sensor has native 16-bit A/D on-chip. The output is real 16-bits with 65536 levels. Compared to 12-bit and 14-bit A/D, a 16-bit A/D yields higher sample resolution and the system gain will be less than 1e-/ADU with no sample error noise and very low read noise.

20210602659BSI: One benefit of the back-illuminated CMOS structure is improved full well capacity. This is particularly helpful for sensors with small pixels. In a typical front-illuminated sensor, photons from the target entering the photosensitive layer of the sensor must first pass through the metal wiring that is embedded just above the photosensitive layer. The wiring structure reflects some of the photons and reduces the efficiency of the sensor. In the back- illuminated sensor the light is allowed to enter the photosensitive surface from the reverse side. In this case the sensor’s embedded wiring structure is below the photosensitive layer. As a result, more incoming photons strike the photosensitive layer and more electrons are generated and captured in the pixel well. This ratio of photon to electron production is called quantum efficiency. The higher the quantum efficiency the more efficient the sensor is at converting photons to electrons and hence the more sensitive the sensor is to capturing an image of something dim.

20210602540Zero Amplify Glow: This is also a zero amplifer glow camera.

20210602542TRUE RAW Data: In the DSLR implementation there is a RAW image output, but typically it is not completely RAW.  Some evidence of noise reduction and hot pixel removal is still visible on close inspection.  This can have a negative effect on the image for astronomy such as the “star eater” effect.  However,  QHY Cameras offer TRUE RAW IMAGE OUTPUT and produces an image comprised of the original signal only, thereby maintaining the maximum flexibility for post-acquisition astronomical image processing programs and other scientific imaging applications.

20210602234Anti-Dew Technology: Based on almost 20-year cooled camera design experience, The QHY cooled camera has implemented the fully dew control solutions. The optic window has built-in dew heater and the chamber is protected from internal humidity condensation. An electric heating board for the chamber window can prevent the formation of dew and the sensor itself is kept dry with our silicon gel tube socket design for control of humidity within the sensor chamber.

20210602302Cooling: In addition to dual stage TE cooling, QHYCCD implements proprietary technology in hardware to control the dark current noise.

Specifications

QHY600PH

QHY600
CMOS Sensor Sony IMX455
Mono/Color Both Available (while Mono only with QHY600PH-L)
FSI/BSI BSI
Pixel Size 3.76um x 3.76um
Effective Pixel Area 9576*6388
(9600*6422 with overscan and optically black area)
Effective Pixels 61.17 Megapixels
(effective area.
Sensor Size Full Frame 36mm x 24mm
A/D Sample Depth 16-bit (0-65535 levels) at 1X1 binning
18-bit at 2X2, 19-bit at 3X3, 20-bit at 4X4 software binning
*QHY600 uses the software digital binning for 2*2binning. With digital sum, 2*2binning will be four 16-bit summed then it is 18-bit.
Full Well Capacity (1×1, 2×2, 3×3) Standard Mode
>51ke- / >204ke- / >408ke-
Super Full Well Mode
>80ke- / >320ke- / >720ke-
Full Frame Rate USB3.0 Port Image Transfer Speed
Full Frame Size: 4.0FPS (8-bit output)
Full Frame Size: 2.5FPS (16-bit output)
7.2FPS at 9600×3194, 22.5FPS at 9600×1080, 28FPS at 9600×768, 47FPS at 9600×480, 160FPS at 9600×100,
Fiber Port Image Transfer Speed (QHY600Pro only)
Full Frame Size: 4.0FPS (16-bit output)
Readout Noise 1.0e- to 3.7e- (Standard Mode)
Dark Current 0.0022e-/p/s @ -20C 0.0046e-/p/s @ -10C
Exposure Time Range 40us – 3600sec
Unity Gain* 25 (Extended Full Well Mode) *
Amp Control Zero Amplifer Glow
Firmware/FPGA remote Upgrade Supported. Via Camera USB Port
Shutter Type Electric Rolling Shutter
Computer Interface USB3.0
Built-in Image Buffer DDR3 memory
PH & PH SBFL ver.: 2GBytes(16Gbit)
Lite ver. : 1GBytes(8Gbit)
Hardware Frame Sequence Number Supported
Cooling System Dual Stage TEC cooler:
– Long exposures (> 1 second) typically -35C below ambient
– Short exposure (< 1second) high FPS, typically -30C below ambient(Test temperature +20°)
Optic Window Type AR+AR High Quality Multi-Layer Anti-Reflection Coating
Anti-Dew Heater Yes
Telescope Interface M54/0.75
Back Focal Length QHY600PH&QHYPH-L: 17.5mm+6mm (±0.2)
QHY600SBFL: 14.5mm*
*The BFL Consumed equals 12.5mm when connecting QHYCFW. About the defination of “BFL Comsumed” and our adapter system please view: https://www.qhyccd.com/adapters/
Weight PH Version: 850g
Lite Version: 790g
Power 40W/100%
20W/50%
13.8W/0%
QHY600PHArticles
Lcot Telescope

NASA Terminal Transmits First Laser Communications Uplink to Space

Article written by nasa.gov. Credits: NASA NASA’s LCOT (Low-Cost Optical Terminal), a ground station made of modified commercial hardware, transmitted its first laser...
PlaneWave Enclosures

PlaneWave Instruments Unveils Revolutionary Enclosures for Telescopes and Advanced Instrumentation

ADRIAN, MI — September 19, 2024 — PlaneWave Instruments, a global leader in the design and manufacture of high-tech observatory-class telescopes, is proud to announce...
Las Cumbres Observatory

Empowering Global Astronomy and Education: PlaneWave Instruments’ Collaboration with Las Cumbres Observatory

Las Cumbres Observatory (LCO) operates a groundbreaking network of 25 robotic telescopes strategically positioned across seven professional astronomy sites around the...